LETTER TO EDITOR
Year : 2017  |  Volume : 11  |  Issue : 4  |  Page : 506-507

Using angle connector? Be careful: A hazard note


Department of Anesthesiology and Critical Care, Rural Medical College, Loni, Maharashtra, India

Correspondence Address:
Akshaya Narayan Shetti
Department of Anesthesiology and Critical Care, Rural Medical College, Pravara Institute of Medical Sciences, Loni Budruk, Maharashtra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/sja.SJA_226_17

Rights and Permissions
Date of Web Publication22-Sep-2017
 


How to cite this article:
Shetti AN. Using angle connector? Be careful: A hazard note. Saudi J Anaesth 2017;11:506-7

How to cite this URL:
Shetti AN. Using angle connector? Be careful: A hazard note. Saudi J Anaesth [serial online] 2017 [cited 2023 Mar 23];11:506-7. Available from: https://www.saudija.org/text.asp?2017/11/4/506/206842



Sir,

Various problems associated with breathing circuit such as leakage, obstruction or kinking, condensation of water, and oxygen delivery devices have been reported earlier.[1],[2],[3],[4] It is important to have a random check of lifesaving equipment supplied in the hospital. Although the supplied materials fulfill the country's rules and regulations, as an end user, quality has to be reconfirmed. The angle connector with side port is most commonly used in operation theater for end-tidal CO2 monitoring. This is also used in case of critical care areas to avoid repeated arterial sampling for the assessment of carbon dioxide levels. In our case, during a routine inspection, the angle connector of breathing system was normal in appearance externally [Figure 1]a, but a plastic projection was found inside the lumen [Figure 1]b. This could be mainly due to the improper manufacturing or lack of quality check. If at all it is used on patient, the problems that may occur are increase in airway resistance and aspiration of the dislodged plastic projection leading to obstruction of airways and collapse of pulmonary segments. Such conditions may lead to life-threatening complications and are rare to diagnose. Rising competition in pricing of medical equipment may lead to compromised or low-quality production. As an end user, we should have a high index of suspicion to identify such problems and should make a habit of quality checking of the materials supplied.
Figure 1: Angle connector (a) normal external appearance (b) inside view - plastic projection (arrow)

Click here to view


Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
  References Top

1.
Punj J, Batra M, Darlong V, Pandey R. Leak in circuit: An unusual cause! J Anaesthesiol Clin Pharmacol 2012;28:133-4.  Back to cited text no. 1
    
2.
Desai S, Torgal S, Rao R. Breathing circuit obstruction caused by kink in the reinforced kink-resistant circle system tube. Indian J Anaesth 2013;57:96-7.  Back to cited text no. 2
[PUBMED]  [Full text]  
3.
Chellam S, Dalal KS, Toal PV. Use of filters in anaesthesia: Is it warranted? Indian J Anaesth 2014;58:475-7.  Back to cited text no. 3
[PUBMED]  [Full text]  
4.
Shetti AN, Dhulkhed VK, Roshansingh D, Khyadi S. Mechanical errors in oxygen humidifier. Saudi J Anaesth 2014;8:302-3.  Back to cited text no. 4
[PUBMED]  [Full text]  


    Figures

  [Figure 1]



 

Top
 
Previous article    Next article
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  IN THIS Article
   References
   Article Figures

 Article Access Statistics
    Viewed2064    
    Printed56    
    Emailed0    
    PDF Downloaded86    
    Comments [Add]    

Recommend this journal