ORIGINAL ARTICLE
Year : 2021  |  Volume : 15  |  Issue : 4  |  Page : 396-402

Comparative performance of two protective barriers during tracheal intubation of COVID-19 patients: A simulation cross-over study


1 Department of Anesthesia, King Faisal Specialist Hospital and Research Center, Riyadh, Saudi Arabia
2 Department of Epidemiology and Scientific Computing, King Faisal Specialist Hospital and Research Center, Riyadh, Saudi Arabia

Correspondence Address:
Abdullah B Abolkheir
Department of Anesthesiology, King Faisal Specialist Hospital and Research Center, MBC 22, Riyadh - 11211, Al Mathar Ash Shamali, Postal Code - 11211, P.O. Box - 3354, Riyadh
Saudi Arabia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/sja.sja_274_21

Rights and Permissions

COVID-19 was declared a pandemic by the WHO in 2020. In light of the global shortage of PPE and concerns regarding the safety of healthcare providers, clinicians have resorted to the use of novel protective barriers, such as aerosol boxes and plastic sheets, during aerosol generating procedures, especially tracheal intubation. We compared the effect of these barriers on the tracheal intubation of simulated patients with severe COVID-19 in a crossover study. The study was approved by the Ethics Committee of King Faisal Specialist Hospital, and the procedures were compliant with the COVID-19 airway management guidelines of the Saudi Anesthesia Society. The time to intubation was our primary outcome. Secondary outcomes included number of optimization maneuvers, number of intubation attempts, time to glottic view and ventilation of the lungs, and damage to PPE. Thirteen consultant anesthetists performed 39 tracheal intubations on a manikin using each of three approaches (aerosol box, plastic sheet, and no-barrier). Data were collected via direct and video observation. The plastic sheet approach demonstrated the highest time to intubation (mean ± StE [95% CI]: 33.3s ± 3.5 [25.8– 40.9]) compared to the aerosol box (22.0s ± 2.5 [16.5 – 27.5], P < 0.01) and no-barrier approaches (16.1s ± 1.1 [13.7 – 18.4], P < 0.0001). Similarly, the plastic sheet approach had the highest time to glottic view, and ventilation intervals compared to the other two approaches, while the no-barrier approach had the shortest time intervals. There were no failed intubations or damage to the PPE sustained during the use of any of the three approaches. The aerosol box does not impose a significant delay in tracheal intubation using video laryngoscopy, unlike the plastic sheet barrier. Further research on the aerosolization risk is warranted before these protective barriers can be considered as mainstay approaches during aerosol generating procedures.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed550    
    Printed8    
    Emailed0    
    PDF Downloaded112    
    Comments [Add]    

Recommend this journal